13) Disconnect the terminal of shift lock solenoid
unit from connector, using a flat-tip screwdriver with
thin tip.
(A) "P" range switch terminal
(B) Shift lock solenoid terminal
B: INSTALLATION
Install in the reverse order of removal.
NOTE:
• Refer to "COMPONENT" for each tightening
torque. <Ref. to CS-3, COMPONENT, General De-
scription.>
• When installing the guide plate, shift the select
lever to "D" range (normal mode position), care
should be taken in the following points.
(1) Insert the protrusion (B) of guide plate into
the hole of shift lock solenoid unit (A).
(2) Insert the link (D) of shift lock release into
the link (C) of shift lock solenoid unit.
b
a
b
(D)
(C)
Shift Lock Solenoid
(B)
(A)
4
3
2 1
10
9 8 7
6 5
CS-00309
a
(B)
(A)
CS-00384
CS-34
• Connect the switch and solenoid terminal to con-
nector.
(B) (A)
1 2
5
(A) "P" range switch (Color code: Red)
(B) "P" range switch (Color code: Red)
(C) Shift lock solenoid (Color code: Black)
(D) Shift lock solenoid (Color code: Blue and Red)
(D)
(C)
3 4
6
7 8
9 10
CS-00394