Format
5-7-4 High-speed Jogging Speed Number (3 Words)
Addresses
Format
5-7-5 Low-speed Jogging Speed Number (3 Words)
Addresses
+0 word
+1 word
+2 word
Example: 20
+2 word
Axis
X
Y
This parameter indirectly designates the high-speed jogging speed addresses
for the X and Y axes. The setting is made in two digits, from 00 to 49. The indirect-
ly designated addresses for both axes are as follows:
X axis: 4000 to 4049
Y axis: 8000 to 8049 (NC211 only)
For example, if "20" is set for the Y-axis speed address for high-speed jogging,
the speed registered at speed address 8020 will become the high-speed jogging
speed. For details on how to set speeds, refer to 5-4 Speeds .
+0 word
+1 word
+2 word
Example: 20
+2 word
Axis
X
Y
This parameter indirectly designates the low-speed jogging speed addresses
for the X and Y axes. The setting is made in two digits, from 00 to 49. The indirect-
ly designated addresses for both axes are as follows:
X axis: 4000 to 4049
Y axis: 8000 to 8049 (NC211 only)
For example, if "20" is set for the Y-axis speed address for low-speed jogging, the
speed registered at speed address 8020 will become the low-speed jogging
speed. For details on how to set speeds, refer to 5-4 Speeds .
Address
Initial positioning action number
Address
2003
6003 (NC211 only)
Address
High-speed jogging speed number
Address
2004
6004 (NC211 only)