Omron SYSMAC C500-NC113 Operation Manual page 88

Position control units
Table of Contents

Advertisement

Format
5-7-19 Number of Inching Pulses (3 Words)
Addresses
Format
+0 word
+1 word
+2 word
Acceleration
Initial speed
HIGH-SPEED JOG command
Example: 20
+2 word
Axis
X
Y
This parameter sets the amount of movement along the designated axis when
the INCH command is executed. The number of pulses is set in three digits, from
1 to 100.
+0 word
+1 word
+2 word
Example: 20 (pulses)
+2 word
Address
High-speed jogging
acceleration/deceleration
number
High-speed jogging speed
Address
2025
6025 (NC211 only)
Address
Number of pulses