7-3
Detailed Contents of I/O Refresh Data
7-4
Status Area
Bit
00 to 02
Reserved for system.
03
Operating mode
Indicates the Programmable Controller's operating mode.
OFF: Program Mode
ON: RUN or Monitor Mode
X: 04
Origin search completion
Y: 10
Indicates whether the origin has been established.
OFF: Origin not established.
ON: Origin established.
X: 05
Error reset completion
Y: 11
Indicates whether error reset processing has been completed.
OFF: When the RESET ERROR command is turned OFF.
ON: When the RESET ERROR command has been received and all
processing for clearing the error has been completed.
X: 06
Origin input signal
Y: 12
Indicates the origin input signal status.
OFF: Origin input signal OFF
ON: Origin input signal ON
X: 07
Origin proximity input signal
Y: 13
Indicates the origin proximity input signal status.
OFF: Origin proximity input signal OFF
ON: Origin proximity input signal ON
X: 08
CW limit input signal
Y: 14
Indicates the CW limit input signal status.
OFF: CW limit input signal OFF
ON: CW limit input signal ON
X: 09
CCW limit input signal
Y: 15
Indicates the CCW limit input signal status.
OFF: CCW limit input signal OFF
ON: CCW limit input signal ON
Note The NC113 is not provided with the Y axis.
The Position Control Unit's internal status area is configured of 15 words (eight
words for the NC113) of data. This data is read to the CPU Unit's IR area by
means of the CPU Unit's Intelligent I/O Read instruction (READ).
The following tables show the configuration of the X-axis and Y-axis status
areas. Words 0 to 7 are for the X axis, and words 8 to 14 are for the Y axis. In the
word addresses, "s" represents a free address that can be designated as the
location into which the data is to be read by means of the Intelligent I/O Read
instruction.
Section
Function
7-4