Omron SYSMAC C500-NC113 Operation Manual page 71

Position control units
Table of Contents

Advertisement

5-3-3 Default Values for Positioning Actions
5-4
Speeds
5-4-1 Setting Target Speeds (4 Words)
Addresses
Format
Address
Item
1000
Speed address
Acceleration/deceleration
address
Dwell time address
Output code
Completion code
Positioning action
Sign
5000
Speed address
Acceleration/deceleration
address
Dwell time address
Output code
Completion code
Positioning action
Sign
• No default values are set for positioning actions for addresses other than those
shown above.
• The address 5000 is not available for the NC113.
Axis
X
Y
The target speed is set in six digits, from 0 to 250,000, in units of pulses per se-
cond (pps).
+0 word
+1 word
+2 word
+3 word
Example: 125,000 pps
+2 word
+3 word
Setting range
00 to 49
00 to 99
00 to 29
00 to 499
0 to 5
00 to 9999999
0 to 7
00 to 49
00 to 99
00 to 29
00 to 499
0 to 5
00 to 9999999
0 to 7
Address
4000 to 4049
8000 to 8049 (NC211 only)
Address
Speed
Section
5-4
Default value
(factory setting)
6
3
2
0
0
0
0
6
3
2
0
0
0
0