Omron SYSMAC C500-NC113 Operation Manual page 68

Position control units
Table of Contents

Advertisement

Format (Unit: Pulses)
Setting Target Position Attributes
Format
Sign Data Contents
Additional Information on Setting Target Positions
Target Position Sign
+4 word
+5 word
Example: 2,715,840 pulses
Set the target position's sign, direction, data type (absolute/incremental), and
single-axis/interpolation designation with one digit from 0 to 7. For example, if
the setting is "4," the settings will be CW and absolute, with interpolation.
Sign
+5 word
(1 digit BCD)
Example: 4
0
CW
1
CCW
2
CW
3
CCW
4
CW
5
CCW
6
CW
7
CCW
Note 4 to 7 are available only for the NC211. If set to 4 to 7 and data is transferred from
the CPU Unit to the NC113, an undefined error (8308) will occur.
The target position is set in seven digits BCD (--9999999 to 9999999).
0
CW
1
CCW
2
CW
3
CCW
4
CW
5
CCW
6
CW
7
CCW
Target position (rightmost digits)
Target position (leftmost digits)
Absolute movement
Incremental movement
Absolute movement
Incremental movement
Absolute value
Incremental value
Absolute value
Incremental value
Section
5-3
Single-axis
g
end point
d
i
Interpolation
end point
d
i
Single-axis end point
g
Interpolation end point

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sysmac c500-nc211

Table of Contents