System Messages

The following messages may appear across the top of the operator screen. The appropriate
action for each situation is described.
Table 7: System Messages and Recommended Responses
Message
T1 Card [1–6] Trunk
[A–B] Out of Service
T1 Card [1–46] Trunk
[A–B] Restored
DSP Board [1–6] Node
[A–D] Has Failed
DSP Board [1–6] Has
Failed
Seizure On Line
[001–575]-Expected
Wink, Outgoing Call
Aborted.
Meaning
An alarm condition
occurred on the
specified T1 trunk.
The alarm condition has
been cleared and the T1
trunk is back in service.
6 user channels on the
system are out of
service.
24 user channels on the
system are out of
service.
System configured for
wink start dialout
supervision.
Operator-initiated blast
or
dialout line has seized in
(answered) but no wink
was received.
Action
Check the alarm status
report to determine the
error condition.
None.
Perform a system
shutdown, then power
down the system and
call Customer Support.
Perform a system
shutdown, then power
down the system and
call Customer Support.
Contact the phone
network provider to
verify dialout supervision
type (wink or delay and
reconfigure dialout
supervision for Delay if
necessary.