Avaya CS700 Administration And Maintenance page 380

Meeting exchange 5.0 conferencing server
Hide thumbs Also See for CS700:
Table of Contents

Advertisement

Trunk Alarms
Table 14: Summary of Trunk Alarm Conditions (continued)
Alarm Type
Blue alarm
Loss of 1°
synch
Loss of 2°
synch
Not installed
Maintenance
Misc.
threshold
alarms
OOF (Out of
Frame)
Slip
BPV
380 Administration and Maintenance of the CS700/CS780 Audio Conferencing Server
Cause
Unframed all 1s pattern.
The system releases all
lines currently seized on
the trunk, thus
transmitting a yellow
alarm to the network.
The primary trunk is out
of service.
The secondary trunk is
out of service.
Trunk not installed.
Trunk not config/
enabled.
Signal impairment
exceeds threshold.
Consecutive terminal
framing bits have errors
in their framing patterns,
making the signal
unrecognizable.
Results from poor
synchronization of the
T1 clocks. After a slip,
the system attempts
resynchronization.
Two consecutive
nonzero signal elements
have the same polarity.
Severity
Class
Nonalarm
SA
ed
Minor
NSA
Minor
NSA
Nonalarm
NSA
ed
Nonalarm
SA
ed
Minor
NSA
Clears When
Cessation of all 1s
pattern
The primary trunk is
restored.
The secondary trunk
is restored.
Trunk configured and
enabled by
administrator.
Rate stays under
threshold (15 min)
Midnight
Changes from OS to
in service
Administrator clears
network statistics
A reframe clears an
OOF.
2 of 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs780

Table of Contents