Site Requirements
Table 6: Input Voltage, Frequency, and Current
Input Voltage
Range
AC
System:
100 VAC to
240VAC
Power supplies:
90 VAC to 254
VAC
DC
System:
40 VDC to 60 VDC
Power supplies:
36 VDC to 72 VDC
Note:
A UPS is highly recommended to prevent system shutdown and loss of data
Note:
during power interruptions. It must provide 350 W or greater.

Environmental

The CS700/CS780 Conferencing Server requires these environmental codintions:
Ambient operating temperature:
l
Ambient storage temperature:
l
Relative operating humidity:
l
Maximum power:
l
Ventilation:
l
Operating shock:
l
Non-operating shock:
l
Operating vibration:
l
Non-operating vibration:
l
Storage temperature:
l
Relative humidity:
l
320 Administration and Maintenance of the CS700/CS780 Audio Conferencing Server
Input Frequency
Range
Input Current
System:
Max. continuous: 8.8A@115 VAC
50 Hz to 60 Hz
Single cycle surge max: <10A
Power factor: >.99 (power supplies
support power factor correction
Power supplies:
Thermal dissipation: less than
47 Hz to 63 Hz
1000 BTU/hr.
Max continuous: 920 W (19.2A at
a nominal 48VDC)
Cold start surge current maximum:
10A (typically 110% of the static
source current, <20ms)
5°C to + 40°C (32°F to 104°F)
-40°C to +70°C
5% to 95%, noncondensing at 40°C
300 watts
4 inch minimum, front and back
15 g for 11 ms
30 g for 6 ms
5 Hz to 20 Hz at 0.34 mm (5 g) for the chassis alone
5 Hz to 20 Hz at 0.35 mm (5 g) for the chassis alone
-40°C to 85°C
Less than 95% at 40°C, noncondensing