Table 12: Hardware and Device Messages (continued)
Message Code
4122
4123
4124
4125
4126
4127
4128
Message
DSP node %d test
command: Wrote 0x%d,
got 0x%d
DSP node %d test
parameter: Wrote 0x%d,
got 0x%d
DSP %d test Mem: After
%d cycles, DSP wrote
0x%d, got 0x%d at 0x%d
DSP node %d
Transmission: Sent 0x%d,
got 0x%d at 0x%d
device diagnostic
completed
MVIP Connection
Initialization Failed, Result
%d
DSP node %d: responded
to %d at 0x%d
Log Message Codes
Meaning
During the specified DSP
test, the specified
command was written, but
the DSP got a different one
or did not recognize the
command.
During the specified DSP
test, the specified
parameter was written, but
the DSP got a different one
or did not recognize the
parameter.
After the specified number
of cycles of the specified
DSP memory test, the DSP
wrote the specified value
and got a different one at
the specified location.
During the specified MVIP
transmission test, the DSP
sent the specified byte and
received a different value
at the specified word
address.
A diagnostic for the
specified device has been
completed. Problems, if
any, have already been
logged.
Initialization of the T1/MVIP
switch connection failed
with the specified result
code.
During DSP testing, the
specified DSP node
responded to a write
request that was intended
for the specified DSP
response node at the
specified location.
Issue 1 August 2007
7 of 8
377