Avaya CS700 Administration And Maintenance page 133

Meeting exchange 5.0 conferencing server
Hide thumbs Also See for CS700:
Table of Contents

Advertisement

Table 23
lists and describes Synchronization & Monitoring parameters.
Table 23: Synchronization & Monitoring Parameters
Parameter
Primary Board
Primary Source
Use Backup?
Backup Board
Backup Source
Poll Period
Slip Limit
BPV Limit
CRC Limit
Description
Specifies the board through which the primary
clocking source is obtained (via the network,
internally, or externally). Valid entries include:
Board 1 (2, 3, ...6)
l
External
l
When this field is set to External, the Primary
Source field is automatically set to H.110 Bus
and some other board must provide the system
clock.
Specifies the primary clocking source: Valid
entries include:
Trunk (A, B, . . . .)
l
Internal
l
H.110 Bus
l
When this field is set to H.110 Bus, the Primary
Board field is automatically set to External and
some other board must provide the system clock.
Specifies whether a backup clocking source
should provide synchronization if the primary
clocking source fails.
Specifies the board through which the backup
clocking source is obtained (via the network or
internally).
Specifies the backup clocking source:
Trunk (A, B, . . . .)
l
Internal
l
Interval in milliseconds between board polls.
Specifies the number of synchronization failures
before the system generates an alarm.
Specifies the number of bi-polar violations before
the system generates an alarm.
Specifies the number of frame cyclic redundancy
check errors before the system generates an
alarm.
Configuring Network Settings
1 of 2
Issue 1 August 2007
133