System Maintenance Options
Table 25: Signaling Details Parameter
Parameter
Wink Time (100-1000 ms)
Min Wink (100-1000 ms)
PreWink Delay (1-10 sec)
Delay Before Dialing
Collect ANI/DNIS
Digits
Timeout (1000-20000 ms)
138 Administration and Maintenance of the CS700/CS780 Audio Conferencing Server
Description
Specifies the length of a valid wink signal for an incoming
call. When a trunk is configured for WINK START for
incoming calls and it detects the far end has gone off
hook, it winks back to the far end by going off hook.
The default value is 200 ms.
The range is 100 to 1000 ms.
Specifies the minimum length of a valid wink back from a
far end.
The default value is 100 ms.
The range is 100 to 1000 ms.
Specifies the amount of time the near end waits before it
winks back to the far end after detecting that the far end
goes off hook.
The default value is 1 sec.
The range is 1 to 10 sec.
When Trunk Out-Signaling is set to DELAY this setting
specifies the interval to wait after the dial out channel
goes off-hook before the system dials any digits.
When Trunk Out-Signaling is set to WINK this setting
specifies the interval to wait after the wink is received
before the system dials any digits.
The default value is 100 ms.
The range is 50 to 5000 ms.
When set to true, this specifies whether or not ANI or
DNIS digits or both are collected, regardless of Trunk
In-Signaling setting.
The default value is false.
The aggregate number of ANI and DNIS digits the
system collects. The system processes a maximum of 24
ANI digits and 16 DNIS digits
The default value is 4.
The range is 1 to 40.
The interval during which the system waits for ANI and
DNIS digits.
The default value is 8000 ms.
The range is 1000 to 20000 ms.