System and Log Messages
Table 12: Hardware and Device Messages (continued)
Message Code
4014
4015
4016
4019
4020
4100
4101
372 Administration and Maintenance of the CS700/CS780 Audio Conferencing Server
Message
Cannot initialize alarms
Network %s failure
Cannot get/set DSP
register for board %d
Put_(in) active error
Read_intr error
device diagnostic failed
device diagnostic passed
Meaning
Failed to set real-time I/O
operation to allow the read/
write access necessary to
placate the deadman timer.
A library call to (enable or
disable) a network card
returned failure. Will always
follow a 4007 when logged
from maintenance.
A request to the DSP driver
to read or write a register
on the specified DSP board
has failed.
An attempt to set a DSP
node active or inactive has
failed.
The event process failed to
read a interrupt message
from the DSP driver.
The diagnostic for the
specified device failed.
The diagnostic for the
specified device was
completed with no
problems found.