DGS-3700 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
DGS-3700-12:5#config wac authorization attributes local disable
Command: config wac authorization attributes local disable
Success.
DGS-3700-12:5#
config wac ports
Purpose
Syntax
Description
Parameters
Restrictions
Example usage:
To configure the WAC port state:
DGS-3700-12:5#config wac ports 1-8 state enable
Command: config wac ports 1-8 state enable
Success.
DGS-3700-12:5#
To configure the WAC port aging time:
DGS-3700-12:5#config wac ports 1-5 aging_time 200
Command: config wac ports 1-5 aging_time 200
Success.
DGS-3700-12:5#
To configure the WAC port parameters.
config wac ports [<portlist> | all] {state [enable | disable] | aging_time [infinite |
<min 1-1440>] | idle_time [infinite | <min 1-1440>] | block_time [<sec 0-300>] }
This command is used to configure the WAC port parameters.
<portlist> - Specifies a range of ports to be configured.
all - Specifies to configure all ports.
state - Specifies to enable or disable the WAC state.
enable - Enable the WAC state.
disable - Disable the WAC state.
aging_time - A time period during which an authenticated host will be kept in
authenticated state. The default value is 24 hours.
infinite - Indicates the authenticated host on the port will not ageout.
<min 1-1440> - Set the ageout between 1 and 1440 minutes.
idle_time - A time period after which an authenticated host will be moved to un-
authenticated state if there is no traffic during that period.
The default value is infinite.
infinite - Indicates the host will not be removed from the authenticated state due to
idle of traffic.
<min 1-1440> - Set the idle time between 1 and 1440 minutes.
block_time - If a host fails to pass the authentication, it will be blocked for this period
of time before it can be re-authenticated..The default value is 60 seconds.
<sec-0-300> - Set the block time between 0 and 300 seconds
Only Administrator and Operator-level users can issue this command.