DGS-3700 Series Layer 2 Managed Gigabit Ethernet Switch CLI Reference Guide
config ddm ports
6.5535 mW. For the received power threshold: when the operating parameter rises
above this value, action associated with alarm is taken. The range of this parameter
is 0 to 6.5535 mW.
low_alarm - Specify low threshold for alarm. For the temperature threshold: when the
operating parameter falls below this value, action associated with alarm is taken.
The range of this parameter is -128 to 127.996 Celsius degrees. For the voltage
threshold: when the operating parameter falls below this value, action associated
with alarm is taken. The range of this parameter is 0 to 6.55 voltages. For the bias
current threshold: when the operating parameter falls below this value, action
associated with alarm is taken. The range of this parameter is 0 to 131 mA. For the
output power threshold: when the operating parameter falls below this value, action
associated with alarm is taken. The range of this parameter is 0 to 6.5535 mW. For
the received power threshold: when the operating parameter falls below this value,
action associated with alarm is taken. The range of this parameter is 0 to 6.5535
mW.
high_warning - Specify high threshold for warning. For the temperature threshold:
when the operating parameter rises above this value, action associated with
warning is taken. The range of this parameter is -128 to 127.996 Celsius degrees.
For the voltage threshold: when the operating parameter rises above this value,
action associated with warning is taken. The range of this parameter is 0 to 6.55
voltages. For the bias current threshold: when the operating parameter rises above
this value, action associated with warning is taken. The range of this parameter is 0
to 131 mA. For the output power threshold: when the operating parameter rises
above this value, action associated with warning is taken. The range of this
parameter is 0 to 6.5535 mW. For the received power threshold: when the
operating parameter rises above this value, action associated with warning is taken.
The range of this parameter is 0 to 6.5535 mW.
low_warning - Specify low threshold for warning. For the temperature threshold:
when the operating parameter falls below this value, action associated with
warning is taken. The range of this parameter is -128 to 127.996 Celsius degrees.
For the voltage threshold: when the operating parameter falls below this value,
action associated with warning is taken. The range of this parameter is 0 to 6.55
voltages. For the bias current threshold: when the operating parameter falls below
this value, action associated with warning is taken. The range of this parameter is 0
to 131 mA. For the output power threshold: when the operating parameter falls
below this value, action associated with warning is taken. The range of this
parameter is 0 to 6.5535 mW. For the received power threshold: when the
operating parameter falls below this value, action associated with warning is taken.
The range of this parameter is 0 to 6.5535 mW.
state - Specify the DDM state and/or DDM shutdown action when encountering an
exceeding alarm or warning threshold event.
enable - Enable the DDM state.
disable - Disable the DDM state. If the DDM state is disabled, no DDM action will
take effect.
shutdown - Specify whether or not to shut down the port on which the operating
parameter exceeds the corresponding alarm or warning threshold. Note that the
port being shut down cannot recover to normal operation automatically. Use the
config ports x state enable command to recover the port.
alarm - Specify whether or not to shut down the port, on which the operating
parameter exceeds the corresponding alarm threshold.
warning - Specify whether or not to shut down the port, on which the operating
Page | 17