B. Connect the telephone labeled B to the modular adapter position associated with Port 1.
C. Connect the telephones labeled A and C to the two test telephone RJ11 jacks.
D. From telephone A, dial the extension number associated with telephone B.
E. Does telephone B ring?
YES ➧
Answer the call, verify the circuit quality, and move telephone B to the next VP 300
RJ11. Continue the procedure until all extensions are tested, then go to Step 3.
➧
NO
Determine the cause and correct the problem before continuing.
3. PBX FUNCTIONAL TEST
Verify that each VP 300 port extension can initiate a transfer by doing a hookswitch flash and a
transfer code or just a hookswitch flash, before dialing an extension number. Also, verify that
you can reconnect to the caller when the extension called is not answered or busy.
A. Connect telephone B to the modular adapter position associated with port 1 of the VP 300.
B. From telephone A, call the extension number associated with telephone B.
C. Answer telephone B and perform a hookswitch flash.
D. Does the PBX provide stutter or solid dial tone after the hookswitch flash?
YES ➧
If either tone is present, continue to E.
➧
NO
Stop and correct the problem before continuing.
E. Dial the transfer initiate code, if any; then dial the extension number associated with
telephone C.
F. After several ringbacks have occurred, perform a hookswitch flash and reconnect code, if
required, to reconnect to telephone A.
G. Did telephone C stop ringing? Did you get reconnected to telephone A, which was on hold?
YES ➧
Connect telephone B to the next VP 300 port extension and continue until the
extensions for each port has been tested.
➧
NO
Determine the cause and correct the problem before continuing.
H. Make telephone C busy by taking it off-hook. Then repeat the test starting with step A and
calling a busy extension instead of the ring no answer extension.
The extension number connected to telephone C should start with the same first digit as
those configured in the USER Table.
4. CALLS TO THE INTERCEPT EXTENSION (ATTENDANT)
Verify each extension can transfer a call to the intercept extension (attendant).
A. Connect telephone B to the modular adapter position associated with port 1 of the VP 300.
B. From telephone A, call the extension number associated with telephone B.
C. Answer telephone B and perform a hookswitch flash and dial the transfer code, if required,
then dial 0 (or the attendant's extension number), then hang-up telephone B.
INSTALLATION
3-37
Toshiba VP Systems Release 7.1