Continued - Toshiba VP 300 Installation Instructions Manual

Voice processing
Table of Contents

Advertisement

Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
24: PBX Integration

(continued)

0A
INTEGRATION TYPE CONFIGURED DOES NOT MATCH
INTEGRATION CARD INSTALLED:
REMEDY:
CAN'T FORWARD A PORT VIA MIC SINCE EXTENSION TO FORWARD
0B =
PORT TO IS NOT DEFINED
0C =
UNEXPECTED CARD STATE
DATA-2 = CARD STATE
00 =
01 =
02 =
03 =
DATA-3 = TASK STATE
00 =
01 =
02 =
03 =
REMEDY:
Clear Hardware Error Table. If error continues, call
Toshiba Technical Support.
0D =
TIMED OUT WAITING FOR STATUS BITS TO CHANGE (TO RUN OR
FAIL AFTER DOWNLOAD COMPLETE)
REMEDY:
Clear Hardware Error Table. If error continues, call
Toshiba Technical Support.
0E =
DETECTED DCD TRANSITION ON RS-232 DATA LINK
Source
Problem with the
This error pertains only to certain
Integration Card
integrated systems. The following
outlines the probable cause and
suggested remedy for that error,
depending upon the DATA fields.
Be sure configuration in the SLOTS Table for the VP 300
matches the integration card type.
RESET
FATAL ERROR
DOWNLOAD
CARD UP
RESET
DOWNLOAD
WAIT AFTER DOWNLOAD
UP
MAINTENANCE
Remedy
Priority
Toshiba VP Systems Release 7.1
July, 1994
5-63