Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
38: Disk Defect Boot
Region
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE XBOOT
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
39: Disk Defect File
System Region
DATA-1 =
LOGICAL DRIVE ID WITH DEFECTIVE FILE SYSTEM
DATA-2 =
NOT USED
DATA-3 =
NOT USED
DATA-4 =
NOT USED
40: Non-Media Disk
Error
DATA-1 :
DRIVE ID AND SEVERITY INDICATION
01
=
02
=
03
=
04
=
05
=
06
=
81
=
82
=
83
=
84
=
85
=
86
=
DATA-2 =
SCSI SENSE KEY
DATA-3 =
SCSI SENSE CODE
DATA-4 =
NOT USED
Source
Defect in secondary
Attempt to reload the software code
bootstrap (Xboot)
from the floppy diskette to the hard disk.
region.
If error repeats, replace the hard disk
indicated in DATA-1. If error repeats
again, call Toshiba Technical Support.
Defect in file system
Attempt to reload the software code
region of a system
from the floppy diskette to the hard disk.
disk.
If error repeats, replace the hard disk
indicated in DATA-1. If error repeats
again, call Toshiba Technical Support.
Non-media disk
Call Toshiba Technical Support to have
error.
information interpreted.
NON-FATAL ERROR, DRIVE 1
NON-FATAL ERROR, DRIVE 2
NON-FATAL ERROR, DRIVE 3
NON-FATAL ERROR, DRIVE 4
NON-FATAL ERROR, DRIVE 5
NON-FATAL ERROR, DRIVE 6
FATAL ERROR, DRIVE 1
FATAL ERROR, DRIVE 2
FATAL ERROR, DRIVE 3
FATAL ERROR, DRIVE 4
FATAL ERROR, DRIVE 5
FATAL ERROR, DRIVE 6
MAINTENANCE
Remedy
Priority
Toshiba VP Systems Release 7.1
5-71
3
3
1
3
July, 1994