Toshiba VP 300 Installation Instructions Manual page 70

Voice processing
Table of Contents

Advertisement

3-14
Installation and Maintenance Manual
To block access to a modem using # # # 5, set system parameter 223 — DISABLE # # # 5 ACCESS
TO THE MODEM to YES.
After the modem access mailbox is created, to connect to the internal modem via the modem access
mailbox:
1. Call the VP 300.
2. When the company greeting plays, enter the mailbox number used for modem access.
3. If Attribute 3 is assigned to the mailbox COS, enter the mailbox security code.
4. After the high-pitched tone, enter the code to connect to the modem (ATD). The code may
vary, depending on interface and modem manufacturer.
If you do not hear a high-pitched tone, repeat steps 1 through 3.
5. Hang up the receiver if step 4 was successful.
The VP 300 automatically adjusts to the modem's baud rate, which must be either 300 or 1200 baud.
* Code may vary depending on interface and modem manufacturer.
Toshiba VP Systems Release 7.1 July, 1994
Call the VP 300
Press
Switch to Data.
Speed is 300 or
1200 Baud.
Do you hear a high–
pitched tone?
Yes!
Enter code to
connect to modem
(ATD)*
Hang up
Figure 3-5 Connecting to VP 300's Internal Modem
5
XYZ Modem
Data
300 1200 2400
Voice
No! (Try again.)
ATD

Advertisement