Error Type:Name
36: System RAM
Error
The DATA-1 field specifies the type of error. DATA-2 through DATA-4 are data associated with
the error.
DATA-1 :
ERROR CODE:
01 =
FIRMWARE REPORT OF RAM SIZE NOT EVEN MEGABYTE
02 =
CANNOT R/W MEM AS REPORTED BY FIRMWARE, SEE DATA-2
DATA-2: (D) = MEGABYTES WHERE ERR, WHEN DATA = 1 OR 2
03 =
RAM SIZE LESS THAN STANDARD SIZE OF 5 MEG (slot = CPU)
04 =
RAM SIZE GREATER THAN STANDARD SIZE OF 5 MEG
(obsolete Release 5.4 and later)
DATA-2: (D) = FIRMWARE REPORT OF MEGABYTES WHEN
DATA-1 = 3 OR 4
05 =
VCU CONTROL RAM > STD SIZE OF 2 MEG
(obsolete Release 5.4 and later)
06 =
VCU VOICE RAM > STD SIZE OF 4 MEG
(obsolete Release 5.4 and later)
07 =
VCU CONTROL RAM < STD SIZE OF 2 MEG (slot = VCU)
(obsolete Release 5.4 and later)
08 =
VCU VOICE RAM < Required amount for port count
(slot = first line card slot that goes beyond limit for existing RAM)
DATA2 = #MB needed for current port configuration
DATA3 = # MB reported by VCU
DATA4 = # ports configured
09 =
VCU CONTROL RAM INSUFFICIENT FOR LANGUAGES LOADED
DATA 2 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 3 = N/A
DATA 4 = N/A
10 =
VCU RAM INSUFFICIENT FOR # FAX PORTS CONFIGURED
DATA 2 = # FAX PORTS SUPPORTED BY VCU RAM
DATA 3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 4 = VCU VOICE RAM SIZE IN MEGABYTES
11 =
VCU RAM INSUFFICIENT FOR # PORTS CONFIGURED
DATA 2 = # PORTS SUPPORTED BY VCU RAM
DATA 3 = VCU CONTROL RAM SIZE IN MEGABYTES
DATA 4 = VCU VOICE RAM SIZE IN MEGABYTES
37: Ring Detection
Failure
DATA-1=
UNEXPECTED EVENT TYPE
DATA-2=
NOT USED
DATA-3=
NOT USED
DATA-4=
NOT USED
Toshiba VP Systems Release 7.1
July, 1994
Table 5-3 Hardware Error Types and Remedies (continued)
Source
Cache module found
an error with system
RAM, CPU and/or
VCU
(if = FF, # ports configured > max expected)
TEST Line 4
Remedy
Call Toshiba Technical Support for
remedy.
Ensure that the PBX is properly
connected to the LIC, and check whether
the PBX type provides sufficient loop
current for the test. If the PBX is
properly connected and the PBX
provides sufficient loop current but the
test still fails, replace the LIC. If the PBX
type does not provide sufficient
loop current, to not use TEST Line 4.
Priority
3
2