5-120
Installation and Maintenance Manual
68
69
70
71
72
Toshiba VP Systems
Release 7.1
July, 1994
DOUBLE INTERRUPTED RINGBACK MINIMUM TONE OFF
SHORT PERIOD
This delay is the shortest a TONE OFF, of the short TONE OFF
period, can be to qualify as double interrupted ringback.
Use — The system uses this delay to determine if the tone cadences it
is monitoring is double interrupted ringback. If the TONE OFF is
shorter than this delay, the system assumes it is not double interrupted
ringback.
SLOW BUSY MAXIMUM TONE ON PERIOD
This delay is the longest a TONE ON can be to qualify as slow busy.
Use — The system uses this delay to determine if the tone cadences it
is monitoring is slow busy. If the TONE ON is longer than this delay,
the system assumes it is not slow busy.
SLOW BUSY MINIMUM TONE ON PERIOD
This delay is the shortest a TONE ON can be to qualify as slow busy.
Use — The system uses this delay to determine if the tone cadences it
is monitoring is slow busy. If the TONE ON is shorter than this delay,
the system assumes it is not slow busy.
SLOW BUSY MAXIMUM TONE OFF PERIOD
This delay is the longest a TONE OFF can be to qualify as slow busy.
Use — The system uses this delay to determine if the tone cadences it
is monitoring is slow busy. If the TONE OFF is longer than this
delay, the system assumes it is not slow busy.
SLOW BUSY MINIMUM TONE OFF PERIOD
This delay is the shortest a TONE OFF can be to qualify as slow
busy.
Use — The system uses this delay to determine if the tone cadences it
is monitoring is slow busy. If the TONE OFF is shorter than this
delay, the system assumes it is not slow busy.