Continued - Toshiba VP 300 Installation Instructions Manual

Voice processing
Table of Contents

Advertisement

5-58
Installation and Maintenance Manual
Error Type:Name
15: System Status
Error (continued)
DATA-1 = FAILURE CODE:
01 =
02 =
03 =
04 =
05 =
06 =
0A =
0B =
0C =
DATA-2 =
Toshiba VP Systems Release 7.1
July, 1994
Table 5-3 Hardware Error Types and Remedies (continued)
Source
Temperature or
voltage out of range.
INSIDE CABINET TEMPERATURE MEASUREMENT IS OUT OF
RANGE.
+5 DIGITAL VOLTAGE MEASUREMENT IS OUT OF RANGE
+12 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
-12 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
+12 MOTOR VOLTAGE MEASUREMENT IS OUT OF RANGE
+5 BATTERY VOLTAGE MEASUREMENT IS OUT OF RANGE
-5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
+5 ANALOG VOLTAGE MEASUREMENT IS OUT OF RANGE
DISK SHUTDOWN CAUSED BY OUT OF RANGE TEMPERATURE
For out of range voltage:
00 = VOLTAGE OUT OF RANGE (DIRECTION UNKNOWN)
01 = VOLTAGE TOO HIGH
02 = VOLTAGE TOO LOW
For out of range temperature:
01 = TEMPERATURE TOO HIGH
02 = TEMPERATURE TOO LOW
For disk shutdown caused by out of range temperature:
01 = SUCCESSFUL SHUT DOWN
02 = FAILED TO SHUT DOWN
Remedy
Check DATA-1 for information
pertaining to what is out of range
and perform corrective action.*
<10 or >50 C (<50 F or >122 F)
+4.75 TO +5.25
+10.80 TO +13.20
-10.80 TO -13.20
+11.40 TO +12.60
+3.60 MINIMUM
-4.50 TO -5.50
+4.50 TO +5.50
<41˚ OR >131˚F (<5˚ OR >55˚C)
Priority
3

Advertisement

Table of Contents
loading

Table of Contents