10.3.7

MITEL SX-2000 MAINTENANCE

The following are the maintenance commands for the Mitel SX-2000 integration.
TEST INTEGRATION This command tells the MIC to run its link selftest. The form of the
(TE INT x 1 or
TE INT x 1)
(TE INT x 1 2)
LIST INTEGRATION
(L INT x 1)
MITEL SX-2000 ADAPTIVE INTEGRATION
command is:
TE INT x 1
where x is the slot number.
Any hardware errors found are logged in the Hardware Error Table. Refer
to the Installation and Maintenance manual — MAINTENANCE,
Hardware Errors.
This command resets the MIC board and takes approximately 30 seconds.
The form of the command is:
TE INT x 1 2
where x is the slot number, and 2 is the reset flag.
This command lists the current state of the MIC board, the diagnostic
status, the status of the links, and the pegs. The form of the command is:
L INT x 1
where x is the slot number.
An example listing is:
@L INT X
********** INTEGRATION STATUS **********
CARD ID = Mitel
CARD STATUS = UP
DIAGNOSTIC = OK
LINK 1 STATUS = ACTIVE
LINK 2 STATUS = IDLE
LINK 3 STATUS = IDLE
LINK 4 STATUS = MSG WAIT
PEGS:
MM/DD HH:MM
INDEPENDENT = 0 0 0 0 0
LINK 1 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 2 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 3 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
LINK 4 = 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Toshiba VP Systems
Release 6.1
February, 1993
10.3-47