When the VP 300 is installed, the levelers should be adjusted until the top of the
Requirements
cabinet is level and does not rock. A bubble level is recommended for this
purpose. No special tools are required to adjust the leveling feet.
Distributor-
Each VP 300 line card is connected via a 25-pair cable to the PBX. Supply one
Supplied
cable per line card (with male/female connectors) sufficiently long enough to
Equipment
reach between the VP 300 and the PBX extension jack without undue stretching
or tension.
The VP 300 may connect via 25-pair cable to punchdown blocks and then be
jumpered to the PBX or Central Office lines. Or, the VP 300 may connect via 25-
pair cable to a breakout adapter that provides standard modular connectors.
A terminal, used for software installation and update, must be available at the
customer site. During installation, an RS-232C cable is required to connect the
terminal to the VP 300. This terminal may be connected to the SP1 connector
located in the front of the chassis or at J1 in the rear of the chassis. If the terminal
is to be permanently installed with the system, connect to J1. If the terminal is
used temporarily during installation and maintenance, connect to SP1. A printer
is useful for making a hard copy of the software configuration.
Table 3-3 lists the equipment provided by the distributor. Refer to Table 3-9 for
additional equipment needed for testing.
Conduit with three
10–gauge wires
DC
Power
Source
Earth Ground
Figure 3-2 Field Wiring for –48 VDC Powered VP 300
Table 3-3
Equipment Provided by Distributor
Item
ASCII terminal (CRT or printer)
RS-232C cable for terminal or printer
INSTALLATION
Terminal Block and Ground
Stud on Back of VP 300
Quantity
1
1
Toshiba VP Systems Release 7.1
3-9
July, 1994