Continued - Toshiba VP 300 Installation Instructions Manual

Voice processing
Table of Contents

Advertisement

Table 5-3 Hardware Error Types and Remedies (continued)
Error Type:Name
15: System Status
Error (continued)
The DATA-1 field specifies the type of error. DATA-2 and DATA-3 are data associated with
the error.
DATA-1 = FAILURE CODE:
01 =
TEMPERATURE OUT OF RANGE
DATA-2::
DATA-3::
02 =
+5D (DIGITAL) SUPPLY OUT OF RANGE
03 =
+12A (ANALOG) SUPPLY OUT OF RANGE
04 =
–12A (ANALOG) SUPPLY OUT OF RANGE
05 =
+12D (DIGITAL) SUPPLY OUT OF RANGE
06 =
+5B (BATTERY) SUPPLY OUT OF RANGE
10 =
LINE CARD NOT ALLOWED
DATA-2 = FIRST PORT # OF LINE CARD NOT ALLOWED.
16: Defect in hard
disk prompt area
DATA-1 =
00 = BOTH SYS DRIVES
01 = SYS DRIVE 1
02 = SYS DRIVE 2
DATA-2 =
LEAST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-3 =
MOST SIGNIFICANT BYTE (Prompt number in HEX)
DATA-4 =
LANGUAGE SET # (1 TO N=n)
Source
Temperature or
Check DATA-1 for information
voltage out of range.
pertaining to what is out of range
and perform corrective action.*
01 = TOO HIGH
01 = TOO LOW
01 = BOTTOM SENSOR OR CARD
02 = TOP SENSOR OR CARD
Defect in prompt
Copy prompts from diskette to the hard
area logged into
disk, using the Floppy Backup Restore
Defect List
procedure. If errors repeat, possible
cause could be HD, VCU.
MAINTENANCE
Remedy
+41F to +113F (+5C to +45C)
+4.90 to +5.15V
+11.40 to +13.30V
–13.60 to –11.40V
+11.40 to +13.30V
+3.60 to +5.50V
Toshiba VP Systems Release 7.1
5-59
Priority
3
3
July, 1994

Advertisement

Table of Contents
loading

Table of Contents