Testing The Battery Charging System - Ducati Diavel Workshop Manual

Hide thumbs Also See for Diavel:
Table of Contents

Advertisement

Diagnostic instruments
The DDS diagnosis instrument will interrogate the electronic control unit and display the parameters analysed with their
relative values.
Operations
Refit the seat

Testing the battery charging system

Note
The on-screen icons used during this procedure are explained in a table at the end of this section.
You can determine the engine rpm required for generator to produce just enough current to charge battery, feed the
injection ignition system and all electric items fitted to motorcycle. When applied to a cable, the clamp-type amperemeter
(1) part no. 88765.1126V detects the magnetic field generated by the current passing through that cable.
Operations
Remove the left belly fairing
Turn on the DDS diagnosis instrument (2) referring to the paragraph
Connect the power and diagnosis cable (Measurement Module) (3) part no. 97900.0222 to the measurement module
connector (D) of the DDS (2).
Section reference
5 - 3,
Refitting the seat
Section reference
5 - 5,
Removal of belly fairing
"Tester power
supply".