Telegram Structure - Siemens SINAMICS G120 Operating Instructions Manual

Inverter with the cu250s-2 control unit (vector)
Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Additional settings
Parameter
p2020
p2022
p2023
p2040
7.7.2.2

Telegram structure

Overview
A USS telegram comprises a series of elements with a defined sequence. Each element
contains 11 bits.
Figure 7-10
Converter with the CU250S-2 Control Unit (vector)
Operating Instructions, 06/2013, FW V4.6, A5E31759476B AB
Description
Setting the baud rate
Value
Baud rate
4
2400
5
4800
6
9600
7
19200
8
38400
Fieldbus interface USS PZD number
Sets the number of 16-bit words in the PZD part of the USS telegram
Setting range: 0... 8 (0 ... 8 words)
Fieldbus interface USS PIV number
Sets the number of 16-bit words in the PIV part of the USS telegram
Setting range:
0, 3, 4: 0, 3 or 4 words
127:
variable length
Fieldbus interface monitoring time [ms]
Sets the monitoring time to monitor the process data received via the fieldbus. If no
process data is received within this time, an appropriate message is output
Structure of a USS telegram
Configuring the fieldbus
7.7 Communication via RS485
Value
Baud rate
9
57600
10
76800
11
93750
12
115200
13
187500
159