Table A- 10
HEX
E
7
4
0
Converter with the CU250S-2 Control Unit (vector)
Operating Instructions, 06/2013, FW V4.6, A5E31759476B AB
Assignment of the control bits in the inverter to the SIMATIC flags and inputs
BIN
Bit in
Significance
STW1
0
0
ON/OFF1
1
1
OFF2
1
2
OFF3
1
3
Operation enable
1
4
Ramp-function generator enable
1
5
Start ramp-function generator
1
6
Setpoint enable
0
7
Acknowledge fault
0
8
Jog 1
0
9
Jog 2
1
10
PLC control
0
11
Setpoint inversion
0
12
Irrelevant
0
13
Motorized potentiometer ↑
0
14
Motorized potentiometer ↓
0
15
Data set changeover
A.8 Application Examples
Bit in
Bit in
Bit in
MW1
MB1
MB2
8
0
9
1
10
2
11
3
12
4
13
5
14
6
15
7
0
0
1
1
2
2
3
3
4
4
5
5
6
6
7
7
Appendix
Inputs
E0.0
E0.6