Parameters of the fault buffer and the fault history
Parameter
r0945
r0948
r0949
p0952
r2109
r2130
r2131
r2133
r2136
Extended settings for faults
Parameter
You can change the fault response of the motor for up to 20 different fault codes:
p2100
p2101
You can change the acknowledgement type for up to 20 different fault codes:
p2126
p2127
You can change up to 20 different faults into an alarm or suppress faults:
p2118
p2119
You will find details in function diagram 8075 and in the parameter description of the List
Manual.
Converter with the CU250S-2 Control Unit (vector)
Operating Instructions, 06/2013, FW V4.6, A5E31759476B AB
Description
Fault code
Displays the numbers of faults that have occurred
Fault time received in milliseconds
Displays the time in milliseconds when the fault occurred
Fault value
Displays additional information about the fault
Fault cases, counter
Number of fault cases that have occurred since the last acknowledgement.
The fault buffer is deleted with p0952 = 0.
Fault time removed in milliseconds
Displays the time in milliseconds when the fault occurred
Fault time received in days
Displays the time in days when the fault occurred
Actual fault code
Displays the code of the oldest fault that is still active
Fault value for float values
Displays additional information about the fault that occurred for float values
Fault time removed in days
Displays the time in days when the fault was removed
Description
Setting the fault number for fault response
Selection of the faults for which the fault response applies
Setting, fault response
Setting the fault response for the selected fault
Setting the fault number for the acknowledgement mode
Selection of the faults for which the acknowledgement type should be changed
Setting, acknowledgement mode
Setting the acknowledgement type for the selected fault
1: Can only be acknowledged using POWER ON
2: IMMEDIATE acknowledgement after removing the fault cause
Setting the message number for the message type
Selection of the message for which the message type should be changed
Setting the message type
Setting the message type for the selected fault
1: Fault
2: Alarm
3: No message
Alarms, faults and system messages
11.4 Faults
375