Communication via RS485
5.3 Communication via USS
5.3.2

Telegram structure

Overview
A USS telegram comprises a series of elements with a defined sequence. Each element
contains 11 bits.
Image 5-1
Telegram part
Start delay / respon-
se delay
STX
LGE
ADR
Net data
BCC
110
Structure of a USS telegram
Description
There is always a start and/or response delay between two telegrams.
Time-out and other errors (Page 118)
An ASCII character (02 hex) indicates the beginning of the message.
The telegram length "LGE" is calculated as follows:
LGE = user data (n bytes) + ADR (1 byte) + BCC (1 byte)
Bit 7 = 0: Normal data exchange.
Bit 7 =1, to transfer telegrams that require a net data structure different
from the device profile.
Bit 6 = 0: Normal data exchange.
Bit 6 = 1: Testing the bus connection: The converter returns the telegram
unchanged to the master.
Bit 5 = 0: Normal data exchange.
(Bit 5 = 1: Not supported in the converter.)
Bits 0 ... 4: Address of the converter.
User data range of the USS telegram (Page 111).
Checksum (exclusive or) across all telegram bytes – with the exception of
BCC.