Table 8- 22
Linear and parabolic characteristics
Requirement
Application examples
The required
Conveyor belts, roller
torque is
conveyors, chain
independent of the
conveyors, eccentric
speed
worm pumps,
compressors,
extruders, centrifuges,
agitators, mixers
The required
Centrifugal pumps,
torque increases
radial fans, axial fans
with the speed
Table 8- 23
Characteristics for special applications
Requirement
Application examples
Applications with a
Centrifugal pumps,
low dynamic
radial fans, axial fans
response and
constant speed
The inverter must
Drives in the textile
keep the motor
sector
speed constant
under all
circumstances.
Freely adjustable
-
U/f characteristic
U/f characteristic
-
with independent
voltage setpoint
Additional information on U/f characteristics can be found in the parameter list and in the
function diagrams 6300 ff of the List Manual.
Converter with the CU250S-2 Control Unit (vector)
Operating Instructions, 06/2013, FW V4.6, A5E31759476B AB
Remark
-
The inverter equalizes the voltage drops
across the stator resistance. Recommended
for motors less than 7.5 kW.
Precondition: You have set the motor data
according to the rating plate and have
performed the motor identification after the
basic commissioning.
Lower losses in the motor and inverter than
for a linear characteristic.
Remark
The ECO mode results in additional energy
saving when compared to the parabolic
characteristic.
If the speed setpoint is reached and
remains unchanged for 5 seconds, the
inverter again reduces its output voltage.
When the maximum current limit is reached,
the inverter only reduces the stator voltage
but not the speed.
-
The interrelationship between the frequency
and voltage is not calculated in the inverter,
but is specified by the user.
Setting functions
8.5 Motor control
Characteristic
Parameter
Linear
p1300 = 0
Linear with Flux
p1300 = 1
Current Control
(FCC)
Parabolic
p1300 = 2
Characteristic
Parameter
ECO mode
p1300 = 4
or
p1300 = 7
Precise
p1300 = 5
frequency
or
characteristic
p1300 = 6
Adjustable
p1300 = 3
characteristic
Independent
p1300 = 19
voltage setpoint