Tmp Event Messages; Tmp8500; Tmp8501 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

TMP Event Messages

TMP8500

Message
I/O Module
Arguments
Detailed
The temperature of the I/O Module identified in the message has increased beyond the
Description
operational range. Thermal protection shut down the I/O Module. Factors external to the I/O
Module may have caused this situation.
Recommended
Check the chassis event log for fan issues and fix any issues present. If no fan issues are
Response Action
detected, check chassis ambient temperature and make sure the temperature is within
operating range. Utilize the RACADM command "racadm getsensorinfo" to check the chassis
ambient temperature.
Category
Audit
SubCategory
TMP = Temperature
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

TMP8501

Message
Unable to read planar board temperature sensors. The cooling has been increased to
safeguard the system.
Detailed
System was unable to read planar board or control panel temperature sensors. The fan speed
Description
was increased to protect system hardware.
Recommended
Remove AC power from the system and reapply AC power. Check to see if the issue is
Response Action
resolved. If the issue persists, contact your service provider.
Category
Audit
SubCategory
TMP = Temperature
arg1 temperature exceeded operating range.
arg1 = iom slot name
Email
LC Log
Alert
FALSE
TRUE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
44