Vdr34; Vdr35 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR34

Message
Background initialization failed for
Arguments
Detailed
Background initialization of a virtual disk failed.
Description
Recommended
Run a consistency check on the virtual disk. If that fails, check the health of the member drives
Response Action
of the virtual disk and then recreate.
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 1 (Critical)
Trap/EventID
4353
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

VDR35

Message
Background initialization has completed for
Arguments
Detailed
Background initialization of a virtual disk completed.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
VDR = Virtual Disk
Severity
Severity 3 (Informational)
Trap/EventID
4355
LCD Message
No LCD message display defined.
Email
LC Log
Alert
TRUE
TRUE
arg1 = virtual disk
Email
LC Log
Alert
TRUE
TRUE
arg1 = virtual disk
LCD
Power Off Power
TRUE
FALSE
arg1 .
LCD
Power Off Power
TRUE
FALSE
arg1 .
Reset
Cycle
FALSE
FALSE
Reset
Cycle
FALSE
FALSE
875