Ctl13; Ctl14 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
The controller and attached enclosures are not cabled correctly.
Description
Recommended
Refer to the storage hardware documentation for information on correct cabling
Response Action
configurations.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 1 (Critical)
Trap/EventID
4329
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CTL13

Message
The
Arguments
Detailed
The controller has flushed the cache and all data in the cache has been lost. This may occur
Description
when the system has memory or battery problems that cause the controller to distrust the
cache. Although user data may have been lost, this alert does not always indicate that relevant
or user data has been lost.
Recommended
Verify that the battery and memory are functioning properly.
Response Action
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 2 (Warning)
Trap/EventID
4330
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CTL14

Message
Single-bit ECC error limit exceeded on the
Email
LC Log
Alert
TRUE
TRUE
arg1 cache has been discarded.
arg1 = Controller name
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 DIMM.
Reset
FALSE
Reset
FALSE
167