Trap/EventID
FALSE
LCD Message
Remote access controller configuration failed. Check screen message
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PST0195

Message
CPU configuration failed.
Detailed
The current processor configuration is unsupported or encountered a fatal exception during
Description
POST. Check the processor configuration. This exception occurred early in system power on,
thus the system may not display video. (BIOS POST exception code C3).
Recommended
Review system processor configuration and reduce the system to the minimum configuration.
Response Action
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
CPU configuration failed. Check screen message
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

PST0196

Message
Incorrect memory configuration.
Detailed
System BIOS detected an invalid memory population. Reinstall the memory to match the
Description
supported population. This exception occurred early in system power on, thus the system may
not display video. (BIOS POST Exception code C4)
Recommended
Re-install memory to match supported memory configuration.
Response Action
Category
System Health
SubCategory
PST = BIOS POST
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Incorrect memory configuration. Review User Guide
506
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE