Mem0004; Mem0020 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

MEM0004

Message
Memory device at location
Arguments
Detailed
The memory may not be seated correctly, misconfigured, or has failed. Memory size is
Description
reduced.
Recommended
Re-install the memory component. Review product documentation for supported memory
Response Action
configurations. If the problem continues, contact support.
Category
System Health
SubCategory
MEM = Memory
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

MEM0020

Message
Memory device at location
Arguments
Detailed
None
Description
Recommended
No response action is required.
Response Action
Category
System Health
SubCategory
MEM = Memory
Email
LC Log
Alert
FALSE
FALSE
arg1 is disabled.
arg1 = location
Email
LC Log
Alert
FALSE
FALSE
arg1 is enabled.
arg1 = location
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
367