Iov011; Iov012 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
FALSE

IOV011

Message
To assign or unassign all affected servers must be powered down.
Detailed
All affected servers must be powered down before an assign or unassign action can be
Description
performed.
Recommended
Power down affected server(s).
Response Action
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
FALSE

IOV012

Message
A license is required to assign VA to non-default server.
Detailed
Non-licensed system default VA 1-4 assignements to servers 1-4 respectivley.
Description
Recommended
Import license which allows customer to assign a PERC VA to any server.
Response Action
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
301

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents