Detailed
The enclosure detected that a power supply unit was removed and is no longer functioning in
Description
optimal condition.
Recommended
Re-insert the power supply unit into the enclosure. Re-connect the AC power cable and switch
Response Action
on the power supply unit. Contact technical support if the issue persists.
Category
Storage
SubCategory
PSU = Power Supply
Severity
Severity 1 (Critical)
Trap/EventID
4233
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PSU1004

Message
Power supply cable has been inserted into
Arguments
Detailed
The enclosure detected that AC power supply was restored to the power supply unit.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
PSU = Power Supply
Severity
Severity 3 (Informational)
Trap/EventID
4235
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

PSU1001

Message
arg1 has failed.
Arguments
520
Email
LC Log
Alert
TRUE
TRUE
arg1 = PSU Sensor Name
Email
LC Log
Alert
TRUE
TRUE
arg1 = PSU Sensor Name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 .
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE