Iov004; Iov005 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
FALSE

IOV004

Message
Unable to turn on PCIe device.
Detailed
The chassis manager is unable to turn on the PCIe device because of one of the following
Description
reasons: 1) PCIe device is not supported, 2) The device is not properly inserted in the slot, 3)
The device is not functioning properly, or 4) The device power requirements exceed the power
available for the slot.
Recommended
Make sure a supported PCIe device is used and that it is properly inserted in the PCIe slot. For
Response Action
a list of supported devices, contact the service provider.
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
FALSE

IOV005

Message
Chassis manager not ready to proccess commands.
Detailed
In order for Chassis to execute most of its command the chassis must be powered on.
Description
Recommended
Power on chassis and retry the command.
Response Action
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
None
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
293

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents