Cpu0702; Cpu0703 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0702

Message
CPU bus parity error detected.
Detailed
System event log and OS logs may indicate that the exception is external to the processor.
Description
Recommended
Check system and operating system logs for exceptions. If no exceptions found, remove input
Response Action
power, reinstall the processor, then apply input power.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
CPU bus parity error detected. Power cycle system
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CPU0703

Message
CPU bus initialization error detected.
Detailed
System event log and OS logs may indicate that the exception is external to the processor.
Description
Recommended
1) Check system and operating system logs for exceptions. If no exceptions are found continue.
Response Action
2) Turn system off and remove input power for one minute. Re-apply input power and turn
system on. 3) Make sure the processor is seated correctly. 4) If the issue still persists, contact
technical support. Refer to the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
CPU = Processor
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
CPU bus initialization error detected. Power cycle system
Initial Default.
FALSE
154
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE

Hide quick links:

Advertisement

Table of Contents
loading