Sel9900; Sel1506 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Category
System Health
SubCategory
SEL = Sys Event Log
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

SEL9900

Message
An unsupported event occurred.
Detailed
The current software version cannot decode this event. The source of the event may come
Description
from a source that is not compatible with this software or the event may have been added after
the release of this software. You may need to review this event using a tool which displays raw
data such as Ipmitool with the -vvv option or Racadm with the -E option.
Recommended
Upgrade Management Software
Response Action
Category
System Health
SubCategory
SEL = Sys Event Log
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

SEL1506

Message
Lost communications with Chassis Group Member
Arguments
Detailed
The primary CMC has lost communication with the indicated member CMC.
Description
Recommended
Check network cable and network connections.
Response Action
704
Email
LC Log
Alert
FALSE
FALSE
Email
LC Log
Alert
FALSE
FALSE
arg1 = number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 .
Reset
FALSE
Reset
FALSE