Ctl52; Ctl53 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
The text for this message is generated by the controller during runtime and can vary depending
Description
on the situation.
Recommended
Make sure the SAS cables attached to the enclosure/backplane are attached securely. Refer
Response Action
to the storage hardware documentation for more information on checking the cables. Contact
technical support if the issue persists.
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 2 (Warning)
Trap/EventID
4330
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CTL52

arg1 SAS port report: arg2
Message
Arguments
Detailed
This alert is provided for informational purposes. The text for this alert is generated by the
Description
controller and can vary depending on the situation.
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
CTL = Storage Contr
Severity
Severity 3 (Informational)
Trap/EventID
4331
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CTL53

Message
A controller hot plug has been detected.
Email
LC Log
Alert
TRUE
TRUE
arg1 = Controller name
arg2 = args
Email
LC Log
Alert
TRUE
TRUE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
187