Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
IOV103
Message
PCIE device
Arguments
Detailed
The Chassis manager has detected the insertion of an adapter card into a slot previously
Description
occuppied.
Recommended
No response action is required.
Response Action
Category
Configuration
SubCategory
IOV = IO Virtualization
Severity
Severity 3 (Informational)
Trap/EventID
10747
LCD Message
No LCD message display defined.
Initial Default.
LCD;#LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
IOV104
Message
Chassis manager unable to allocate
Arguments
Detailed
For each adapter assigned to server power is allocatted when the server is powered on. If the
Description
only portion of the needed power is availiable the Chassis manager will not power on servers
associated adapters.
Recommended
Increase power cap or add additional power supply.
Response Action
Category
System Health
SubCategory
IOV = IO Virtualization
Email
LC Log
Alert
TRUE
TRUE
arg1 in arg2arg3 replaced by PCIE device arg4 ,
arg1 = device name
•
•
arg2 = slot type
arg3 = slot number
•
arg4 = device name
•
Email
LC Log
Alert
TRUE
TRUE
arg1 = number of WATTS
•
arg2 = server slot number
•
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
arg1 WATTS for server- arg2 s PCIE adapters.
Reset
FALSE
Reset
FALSE
297