Bat1022; Bat1028 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Severity
Severity 3 (Informational)
Trap/EventID
4275
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

BAT1022

arg1 battery recondition is completed.
Message
Arguments
Detailed
This alert is provided for informational purposes.
Description
Recommended
No response action is required.
Response Action
Category
Storage
SubCategory
BAT = Battery Event
Severity
Severity 3 (Informational)
Trap/EventID
4275
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#LCD;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

BAT1028

Message
The battery voltage on
Arguments
Detailed
The controller battery voltage is low. This may indicate that the battery is no longer protecting
Description
the controller cache.
Recommended
The battery needs to recharged. Wait 24 hours to see if the charge is restored.
Response Action
Category
Storage
68
Email
LC Log
Alert
TRUE
TRUE
arg1 = Controller name
Email
LC Log
Alert
TRUE
TRUE
arg1 is low.
arg1 = controller name
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
LCD
Power Off Power
Cycle
TRUE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents