Cmc8538; Cmc8539 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8538

Message
Firmware version string is too long.
Detailed
The length of the CMC firmware version to be sent in the message from local CMC to peer CMC
Description
is too long. Under these conditions, CMC version in the message is displayed as 1.0.
Recommended
No response action is required.
Response Action
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

CMC8539

Message
The CMC
Arguments
Detailed
CMC cannot log new events to Hardware Log if Hardware Log is full. Therefore, new events
Description
are not written to the log unless older events are cleared. This issue also occurs if event
logging is disabled.
Recommended
Do the following: 1) Save the Hardware Log if required. 2) Clear the Hardware Log.
Response Action
Category
Audit
SubCategory
CMC = Chassis Management Controller
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
122
Email
LC Log
Alert
TRUE
TRUE
Email
LC Log
Alert
FALSE
TRUE
arg1 is unable to log arg2 event to the Hardware Log.
arg1 = slot id
arg2 = event message
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE

Hide quick links: