Rrdu0005 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

RRDU0005

Message
Internal Dual SD Module is not redundant. Insufficient resources to maintain normal
operations.
Detailed
The current operating configuration cannot maintain redundancy.The unit may operate in a
Description
degraded state.
Recommended
Review product documentation and SD card configuration.
Response Action
Category
System Health
SubCategory
RRDU = IDSDM Redundancy
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
Internal Dual SD Module is not redundant. Insufficient resources. Check SD Cards
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
669