Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE
PWR8560
Message
Unable to turn on I/O Module
Arguments
Detailed
Unable to turn on the I/O Module identified in the message due to insufficient chassis power.
Description
Recommended
Utilize the Chassis Management Controller (CMC) web interface to check available power and
Response Action
I/O Module power requirements. If sufficient power is available, restart the CMC and retry the
operation. If sufficient power is not availble due to an insufficient number of PSUs, add
additional PSU(s) and reinsert the I/O Module.
Category
Audit
SubCategory
PWR = Power Usage
Severity
Severity 1 (Critical)
Trap/EventID
8417
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE
PWR8561
Message
Unable to power on server
Arguments
Detailed
The Chassis Management Controller is unable to communicate with the Server iDRAC service
Description
processor and the server could not be powered on. This situation may occur when iDRAC is
rebooting.
Recommended
Wait for three minutes and then retry the operation. If the issue persists, remove and reinsert
Response Action
the server and wait for the iDRAC to finish restarting.
Category
Audit
SubCategory
PWR = Power Usage
576
Email
LC Log
Alert
FALSE
TRUE
arg1 due to insufficient chassis power.
arg1 = IOM slot name
•
Email
LC Log
Alert
TRUE
TRUE
arg1 because of iDRAC communication issue.
arg1 = server number
•
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE