Rdu0003; Rdu0004; Rdu0005 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

RDU0003

Message
Fan redundancy is degraded.
Detailed
One of more fans have failed or have been removed or a configuration change occurred which
Description
requires additional fans.
Recommended
Remove and re-install failed fans or install additional fans.
Response Action
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

RDU0004

Message
The fans are not redundant.
Detailed
One of more fans have failed or have been removed or a configuration change occurred which
Description
requires additional fans.
Recommended
Remove and re-install failed fans or install additional fans.
Response Action
Category
System Health
SubCategory
RDU = Redundancy
Severity
Severity 3 (Informational)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
FALSE
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

RDU0005

Message
The fans are not redundant. Insufficient resources to maintain normal operations.
638
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Email
LC Log
LCD
Alert
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE
Power Off Power
Reset
Cycle
FALSE
FALSE
FALSE

Hide quick links:

Advertisement

Table of Contents
loading