Cmc8523; Cmc8524 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

Detailed
The Mezz card 2 FRU for the server specified in the message is not functioning or CMC is
Description
unable to read it.
Recommended
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
Response Action
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8523

Message
The Mezz card 3 FRU for the server
Arguments
Detailed
The Mezz card 3 FRU for the server specified in the message is not functioning or CMC is
Description
unable to read it.
Recommended
Do the following: 1) Reset iDRAC of the specified server or virtual reseat the server. 2) Reset
Response Action
CMC and wait for a few minutes. If the issue persists, contact your service provider.
Category
System Health
SubCategory
CMC = Chassis Management Controller
Severity
Severity 1 (Critical)
Trap/EventID
2545
LCD Message
No LCD message display defined.
Initial Default.
SNMP Alert;#EMAIL Alert;#LC Log;#Remote System Log
Filter
IPMI Alert SNMP
Visibility
Alert
TRUE
FALSE
TRUE

CMC8524

Message
The Mezz card 4 FRU for the server
Arguments
116
Email
LC Log
Alert
TRUE
TRUE
arg1 = slot number
Email
LC Log
Alert
TRUE
TRUE
arg1 = slot number
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 is not functioning.
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
arg1 is not functioning.
Reset
FALSE
Reset
FALSE

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents