Mem8502; Mem0000 - Dell PowerEdge VRTX Reference Manual

Dell poweredge vrtx chassis management controller firmware event message reference guide version 1.0
Hide thumbs Also See for PowerEdge VRTX:
Table of Contents

Advertisement

LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

MEM8502

Message
ECC Memory error rate failover condition detected.
Detailed
An ECC memory condition was detected on the primary CMC and a failover was initiated.
Description
Recommended
Reseat the primary CMC and initiate a failover back to the primary CMC. If the problem persists
Response Action
and multiple failovers occur, contact your service provider. .
Category
Audit
SubCategory
MEM = Memory
Severity
Severity 1 (Critical)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
Initial Default.
LC Log
Filter
IPMI Alert SNMP
Visibility
Alert
FALSE
FALSE
FALSE

MEM0000

Message
Persistent correctable memory errors detected on a memory device at location(s)
Arguments
Detailed
The memory is operational. This is an early indicator of a possible future uncorrectable error.
Description
Recommended
Re-install the memory component. If the problem persists, contact technical support. Refer to
Response Action
the product documentation to choose a convenient contact method.
Category
System Health
SubCategory
MEM = Memory
Severity
Severity 2 (Warning)
Trap/EventID
FALSE
LCD Message
No LCD message display defined.
364
Email
LC Log
Alert
FALSE
TRUE
Email
LC Log
Alert
FALSE
TRUE
arg1 = location
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
LCD
Power Off Power
Cycle
FALSE
FALSE
FALSE
Reset
FALSE
Reset
FALSE
arg1 .

Hide quick links:

Advertisement

Table of Contents
loading